The following filters are now available in the full 5.75 inch size required for the Mosaic CCD imagers. If you would like to bring your own filters, the physical size should be 146 x 146 mm, and the filter should be 12 mm thick. Properties for the CTIO interference filters shown below are at the f/2.9 of the CTIO 4-m prime focus. Properties shown below for the 4meter filters are for parallel light. Note that most KPNO Mosaic filters (except for the U filter) are parfocal while at CTIO the filters are NOT parfocal - approximate focus offsets can be found on the CTIO Mosaic filters page.

As of April 24, 2012 all CTIO Mosaic-2 filters have been transferred to KPNO and are available for use with Mosaic-1.

IMPORTANT: All filters must be referred to by specific names (listed here) when using the instrument control software at the telescope.

For more information on a filter (e.g. to view transmission curves), click on the filter name. All KPNO Mosaic filters were measured at NOAO.

Mosaic


Filter FWHM (Å) CWL (Å) Telescope Instrument Plot Data Comments
Us solid U k1044 Nicholas U. Mayall 4-meter Telescope Mosaic Us solid U k1044 Us solid U k1044
755 BATC k1061 ** Nicholas U. Mayall 4-meter Telescope Mosaic 755 BATC k1061 ** 755 BATC k1061 **
ha4 H-alpha+4nm k1010 Nicholas U. Mayall 4-meter Telescope Mosaic ha4 H-alpha+4nm k1010 ha4 H-alpha+4nm k1010 Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=6593A, FWHM=81A, PEAK TRANSMISSION=91.1%.
823 823_v1 k1027 70.61 8232.04 Nicholas U. Mayall 4-meter Telescope Mosaic 823 823_v1 k1027 823 823_v1 k1027 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: In December 2003 a replacement for this filter (k1047) was purchased. See below for a comparison of the two filters.
337 BATC k1051 ** Nicholas U. Mayall 4-meter Telescope Mosaic 337 BATC k1051 ** 337 BATC k1051 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
V Harris c6026 940.00 5370.00 Nicholas U. Mayall 4-meter Telescope Mosaic V Harris c6026 V Harris c6026 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.
B Harris k1002 993.88 4381.00 Nicholas U. Mayall 4-meter Telescope Mosaic B Harris k1002 B Harris k1002 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
wh Bk-7 k1016 6800.00 5600.00 Nicholas U. Mayall 4-meter Telescope Mosaic wh Bk-7 k1016 wh Bk-7 k1016 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
zd DECam k1038 *** New! 1467.00 9280.00 Nicholas U. Mayall 4-meter Telescope Mosaic zd DECam k1038 *** New! zd DECam k1038 *** New! Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
527 BATC k1056 ** Nicholas U. Mayall 4-meter Telescope Mosaic 527 BATC k1056 ** 527 BATC k1056 **
wh Bk-7 c6016 5000.00 6500.00 Nicholas U. Mayall 4-meter Telescope Mosaic
I Nearly-Mould k1005 Nicholas U. Mayall 4-meter Telescope Mosaic I Nearly-Mould k1005
wrc4 WR CIV k1024 41.79 5828.71 Nicholas U. Mayall 4-meter Telescope Mosaic wrc4 WR CIV k1024 wrc4 WR CIV k1024 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page.
Ud Dey custom U k1045 329.76 3485.23 Nicholas U. Mayall 4-meter Telescope Mosaic Ud Dey custom U k1045 Ud Dey custom U k1045 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
802 BATC k1062 ** Nicholas U. Mayall 4-meter Telescope Mosaic 802 BATC k1062 ** 802 BATC k1062 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
ha8 H-alpha+8nm k1011 81.33 6654.19 Nicholas U. Mayall 4-meter Telescope Mosaic ha8 H-alpha+8nm k1011 ha8 H-alpha+8nm k1011 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer See the plot at the bottom of the page.
823 823_v1 k1027 Nicholas U. Mayall 4-meter Telescope Mosaic 823 823_v1 k1027 823 823_v1 k1027
337 BATC k1051 ** Nicholas U. Mayall 4-meter Telescope Mosaic 337 BATC k1051 ** 337 BATC k1051 **
R Harris c6004 1510.00 6440.00 Nicholas U. Mayall 4-meter Telescope Mosaic R Harris c6004 R Harris c6004 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.
B Harris k1002 Nicholas U. Mayall 4-meter Telescope Mosaic B Harris k1002 B Harris k1002
g SDSS k1017 1395.73 4750.58 Nicholas U. Mayall 4-meter Telescope Mosaic g SDSS k1017 g SDSS k1017 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
VR k1039 *** New! 2216.00 5940.00 Nicholas U. Mayall 4-meter Telescope Mosaic VR k1039 *** New! VR k1039 *** New! NOTE: This filter is a replacement for k1040. Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
579 BATC k1057 ** Nicholas U. Mayall 4-meter Telescope Mosaic 579 BATC k1057 ** 579 BATC k1057 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
g SDSS c6017 1537.00 4813.00 Nicholas U. Mayall 4-meter Telescope Mosaic g SDSS c6017 g SDSS c6017 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.
C Washington k1006 1034.00 3860.00 Nicholas U. Mayall 4-meter Telescope Mosaic C Washington k1006 C Washington k1006 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page.
wrc4 WR CIV k1024 Nicholas U. Mayall 4-meter Telescope Mosaic wrc4 WR CIV k1024 wrc4 WR CIV k1024 Below is a plot of this filter as simulated in different f/ratio beams. At the KPNO 4m f/3.1 the properties of this filter are: CWL=5819A FWHM=42.17A PEAK TRANSMISSION=71.36%
Ud Dey custom U k1045 Nicholas U. Mayall 4-meter Telescope Mosaic Ud Dey custom U k1045 Ud Dey custom U k1045
802 BATC k1062 ** Nicholas U. Mayall 4-meter Telescope Mosaic 802 BATC k1062 ** 802 BATC k1062 **
ha8 H-alpha+8nm k1011 Nicholas U. Mayall 4-meter Telescope Mosaic ha8 H-alpha+8nm k1011 ha8 H-alpha+8nm k1011 Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=6634A, FWHM=81A, PEAK TRANSMISSION=89.2%.
823 823_v1 k1027 Nicholas U. Mayall 4-meter Telescope Mosaic 823 823_v1 k1027 A comparison of this filter with the newer version (k1047):
390 BATC k1052 ** Nicholas U. Mayall 4-meter Telescope Mosaic 390 BATC k1052 ** 390 BATC k1052 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
I c6028 1500.00 8050.00 Nicholas U. Mayall 4-meter Telescope Mosaic I c6028 I c6028 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.
B Harris k1002 Nicholas U. Mayall 4-meter Telescope Mosaic B Harris k1002
r SDSS k1018 1475.17 6292.28 Nicholas U. Mayall 4-meter Telescope Mosaic r SDSS k1018 r SDSS k1018 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
VR Bernstein k1040 *** Retired! 2119.56 5944.95 Nicholas U. Mayall 4-meter Telescope Mosaic VR Bernstein k1040 *** Retired! VR Bernstein k1040 *** Retired! NOTE: This filter was damaged in June 2011 and is retired. Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page.
579 BATC k1057 ** Nicholas U. Mayall 4-meter Telescope Mosaic 579 BATC k1057 ** 579 BATC k1057 **
r SDSS c6018 1468.00 6287.00 Nicholas U. Mayall 4-meter Telescope Mosaic r SDSS c6018 r SDSS c6018 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.
C Washington k1006 Nicholas U. Mayall 4-meter Telescope Mosaic C Washington k1006 C Washington k1006 Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=3892A, FWHM=1030A, PEAK TRANSMISSION=77.4%.
Bw NDWFS k1025 1275.21 4110.78 Nicholas U. Mayall 4-meter Telescope Mosaic Bw NDWFS k1025 Bw NDWFS k1025 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: This filter was called the NDWFS UB filter in 1997-1998.
815 815_v2 k1046 68.53 8152.64 Nicholas U. Mayall 4-meter Telescope Mosaic 815 815_v2 k1046 815 815_v2 k1046 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: This is a replacement for the old Rhoads 815 filter (k1026)
848 BATC k1063 ** Nicholas U. Mayall 4-meter Telescope Mosaic 848 BATC k1063 ** 848 BATC k1063 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
ha12 H-alpha+12nm k1012 82.95 6698.53 Nicholas U. Mayall 4-meter Telescope Mosaic ha12 H-alpha+12nm k1012 ha12 H-alpha+12nm k1012 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page.
823 823_v1 k1027 Nicholas U. Mayall 4-meter Telescope Mosaic 823 823_v1 k1027
390 BATC k1052 ** Nicholas U. Mayall 4-meter Telescope Mosaic 390 BATC k1052 ** 390 BATC k1052 **
C Washington c6029 1075.00 3850.00 Nicholas U. Mayall 4-meter Telescope Mosaic
V Harris k1003 948.66 5386.76 Nicholas U. Mayall 4-meter Telescope Mosaic V Harris k1003 V Harris k1003 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
i SDSS k1019 1539.89 7726.28 Nicholas U. Mayall 4-meter Telescope Mosaic i SDSS k1019 i SDSS k1019 Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
VR Bernstein k1040 *** Retired! Nicholas U. Mayall 4-meter Telescope Mosaic VR Bernstein k1040 *** Retired! VR Bernstein k1040 *** Retired! Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=5934A, FWHM=2079A, PEAK TRANSMISSION=95.3%.
607 BATC k1058 ** Nicholas U. Mayall 4-meter Telescope Mosaic 607 BATC k1058 ** 607 BATC k1058 ** Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer.
i SDSS c6019 1548.00 7732.00 Nicholas U. Mayall 4-meter Telescope Mosaic i SDSS c6019 i SDSS c6019 Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam.

Below are plots of some of our filter sets. Click on the plot to view full size.

Harris Filters H-alpha Filters SDSS and Washington Filters OIII and DDO51 Filters Wolf-Rayet Filters
Rhoads Filters Windhorst BATC Filters

Notes

* The [OIII] filter is not a good match for the 0.9-m -- a replacement has been proven difficult to construct. For now, there are no alternatives.

** Rogier Windhorst and collaborators at Arizona State University are making available to users of MOSAIC-1 at the Mayall 4m telescope and NOAO time on the WIYN 0.9m telescope 15 medium band filters designed to avoid the brightest and most variable night sky lines. The September 2001 issue of the NOAO newsletter (see page 34) contains an article describing the filters along with references describing their past use by Windhorst and collaborators. A figure showing the throughput curves for the filters is available via the link below. The entire ASU/Windhorst filter set includes 15 filters covering from 3370 angstroms to 9730 angstroms. The filters "Windhorst XXXXXXX a" through "Windhorst XXXXX p" in the above list of Mosaic filters (by serial number these are k1051 through k1065 in the list) can be requested for use.

The BATC filter set belongs to Dr. Rogier Windhorst of Arizona State University. Observers wishing to use these filters should request permission to use these filters from Dr. Windhorst (Rogier.Windhorst@asu.edu) prior to submitting their proposals to the NOAO TAC. Dr. Windhorst will inform NOAO when he has given approval for use of the filter. Please make clear in your request to Dr. Windhorst the following information: Proposed Telescope/Instrument; PI of intended proposal; General Science goals of the proposal.

Rogier Windhorst has provided the following figure showing the transmission of the ASU/Windhorst filter set, Click Here. Note that the filters are labeled a through km through p, these short "letter" names will allow you to match the filters to the wavelength name. For example, "a" corresponds to filter "337 BATC", etc..

*** The KPNO VR Berstein and KPNO SDSS z' filters were damaged in June 2011. The CTIO VR filter (c6027) is also damaged. The new KPNO VR filter (k1039) is now available as a replacement. The CTIO SDSS z' equivalent (c6020) can be requested as replacement for the KPNO z' filter.

Filters Expected Soon!

  • None Pending ...