Filters
Filter | FWHM (Å) | CWL (Å) | Telescope | Instrument | Plot | Data | Comments |
---|---|---|---|---|---|---|---|
[Fe II] | 140.00 | 16400.00 | SOAR Telescope | SPARTAN IR | Width [km/s]: 2630. Note that SPARTAN filters are permanently mounted in the instrument, and therefore are always available and need not be specified in Instrument Setup forms. | ||
[Fe II] | 164.00 | 1646.00 | WIYN 3.5-meter Telescope | WHIRC | [Fe II] | ||
[Fe II] 45 | 162.00 | 1668.00 | WIYN 3.5-meter Telescope | WHIRC | [Fe II] 45 | ||
[O III] | 45.00 | 5008.00 | KPNO 2.1-meter Telescope | KPNO 4-Inch Filters | [O III] | [O III] | |
[O III] -2 | 49.00 | 5011.00 | KPNO 2.1-meter Telescope | KPNO 4-Inch Filters | [O III] -2 | [O III] -2 | new 10/2011 |
[O III] redshifted | 53.00 | 5022.00 | KPNO 2.1-meter Telescope | KPNO 4-Inch Filters | [O III] redshifted | [O III] redshifted | George Jacoby's filter |
[S III] | 27.00 | 9545.00 | KPNO 2.1-meter Telescope | KPNO 4-Inch Filters | [S III] | [S III] | George Jacoby's filter |
0-51 | 0.00 | 0.00 | KPNO 2.1-meter Telescope | GoldCam | 0-51 | 0-51 | Sharp-Cut Filter. Cutoff filter: no transmission peak, FWHM is undefined. |
1056 nm, 1056 | 0.74 | 1056.37 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1056 nm, 1056 | Use with 1403 | |
1060 blocker, 1 μm blocker, 1056 + 1063 blocker | 1063.50 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1060 blocker, 1 μm blocker, 1056 + 1063 blocker | Use with 1401, 1402 | ||
1063 nm, 1063 | 0.81 | 1063.09 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1063 nm, 1063 | Use with 1403 | |
1187 nm 1187, 1.19 μm continuum | 11.10 | 1186.40 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1187 nm 1187, 1.19 μm continuum | Use with 2104. | |
1187 test | 11.60 | 1190.20 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1187 test | Use with 2104. On loan; returned to vendor 05 Feb 2008. These filters have never been used in NEWFIRM. | |
1644 blocker [Fe II] blocker | 451.00 | 1593.00 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1644 blocker [Fe II] blocker | Use with 3301 | |
1644 nm, 1644 | 17.20 | 1649.10 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 1644 nm, 1644 | Use with 3302 | |
2096 nm | 20.40 | 2096.00 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 2096 nm | ||
2124 nm 2124, 2.12 μm H2 | 24.00 | 2131.90 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 2124 nm 2124, 2.12 μm H2 | Use with 4303 | |
2124/68 blocker 2 μm blocker | 257.00 | 2165.00 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 2124/68 blocker 2 μm blocker | Use with 4301, 4302 | |
2168 nm 2168, 2.16 μm Br γ | 24.40 | 2177.00 | Nicholas U. Mayall 4-meter Telescope | NEWFIRM | 2168 nm 2168, 2.16 μm Br γ | Use with 4303 | |
3-75 | 0.00 | 0.00 | KPNO 2.1-meter Telescope | GoldCam | 3-75 | 3-75 | Sharp-Cut Filter. Cutoff filter: no transmission peak, FWHM is undefined. |
337 BATC k1051 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 337 BATC k1051 ** | 337 BATC k1051 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
337 BATC k1051 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 337 BATC k1051 ** | 337 BATC k1051 ** | |||
390 BATC k1052 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 390 BATC k1052 ** | 390 BATC k1052 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
390 BATC k1052 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 390 BATC k1052 ** | 390 BATC k1052 ** | |||
4-96 | 1756.27 | 4724.00 | KPNO 2.1-meter Telescope | GoldCam | 4-96 | 4-96 | Bandpass Filter. |
4-96 | 1643.57 | 4720.96 | Nicholas U. Mayall 4-meter Telescope | RC Spectrograph | 4-96 | 4-96 | Bandpass Filter. |
420 BATC k1053 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 420 BATC k1053 ** | 420 BATC k1053 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
420 BATC k1053 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 420 BATC k1053 ** | 420 BATC k1053 ** | |||
454 BATC k1054 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 454 BATC k1054 ** | 454 BATC k1054 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
454 BATC k1054 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 454 BATC k1054 ** | 454 BATC k1054 ** | |||
493 BATC k1055 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 493 BATC k1055 ** | 493 BATC k1055 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
493 BATC k1055 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 493 BATC k1055 ** | 493 BATC k1055 ** | |||
5019/50 | 50.00 | 5027.00 | SMARTS Consortium: 0.9-meter Telescope | BLANK | 5019/50 | 5019/50 | Size: 4x4 Thick: 7.83 |
527 BATC k1056 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 527 BATC k1056 ** | 527 BATC k1056 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
527 BATC k1056 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 527 BATC k1056 ** | 527 BATC k1056 ** | |||
579 BATC k1057 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 579 BATC k1057 ** | 579 BATC k1057 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
579 BATC k1057 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 579 BATC k1057 ** | 579 BATC k1057 ** | |||
607 BATC k1058 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 607 BATC k1058 ** | 607 BATC k1058 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
607 BATC k1058 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 607 BATC k1058 ** | 607 BATC k1058 ** | |||
660075-3 | 69.00 | 6598.00 | SMARTS Consortium: 0.9-meter Telescope | BLANK | 660075-3 | Size: 3x3 Thick: 5.57 | |
660075-4 | 67.00 | 6600.00 | SMARTS Consortium: 0.9-meter Telescope | BLANK | 660075-4 | Size: 4x4 Thick: 5.57 | |
666 BATC k1059 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 666 BATC k1059 ** | 666 BATC k1059 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
666 BATC k1059 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 666 BATC k1059 ** | 666 BATC k1059 ** | |||
705 BATC k1060 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 705 BATC k1060 ** | 705 BATC k1060 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
705 BATC k1060 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 705 BATC k1060 ** | 705 BATC k1060 ** | |||
755 BATC k1061 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 755 BATC k1061 ** | 755 BATC k1061 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
755 BATC k1061 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 755 BATC k1061 ** | 755 BATC k1061 ** | |||
802 BATC k1062 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 802 BATC k1062 ** | 802 BATC k1062 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
802 BATC k1062 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 802 BATC k1062 ** | 802 BATC k1062 ** | |||
815 815_v1 k1026 | 70.36 | 8152.10 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v1 k1026 | 815 815_v1 k1026 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note:In December 2003 a replacement for this filter (k1046) was purchased. See below for a comparison between the two filters. |
Pagination
Showing 1-50 of 1258