MOSAIC Filters
The Mosaic II imager, used at the Blanco 4-m prime focus, takes filters that are 146x146 mm and 12 mm (nominal) thick. A set of standardized filter names and IDs for both Mosaic I on the KPNO Mayall and Mosaic II on the CTIO Blanco have been developed to ensure proper application of astrometric solutions and real-time display processing (as well as future archive uniformity). These official names are listed in the Mosaic filter list web page.
Focus offsets are referred to the R filter, since this is the filter we use for taking focus frames each night when the Mosaic is installed in order to monitor telescope performance.
Note that the Sloan set (griz) and the Johnson-Cousins BVR (but not I) sets should be near-identical to those at KPNO.
Note: The central wavelength of narrow band filters (actually all filters, but it is very significant for narrow band filters) is shifted approx. 15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelengths quoated below are nominally for when the filters used at PF, with the approx. 15A shift included. Furthermore, the filter transmission curves presented below show the simulated filter tranmission curve for the Blanco 4m + PFADC f/2.87 beam.
Note: The Blanco prime focus corrector has poor response in the UV: 90% (4000A), 85% (3800A), 74% (3650A), 54% (3500A), 31% (3400A), 11% (3350A), 0% (3300A). These are calculations from the glass types and AR coating specifications, and the figures for 3300-3400A are rather uncertain. YOU STRONGLY ENCOURAGED TO USE THE u(SDSS) filter rather than the U filter. Neither of these filters, in combination with the CCDs and optical corrector, match the standard passbands perfectly. The U filter uses a (troublesome!) copper sulphate solution as red blocker, whereas the SDSS u filter is an interference filter.
Mosaic
Filter | FWHM (Å) | CWL (Å) | Telescope | Instrument | Plot | Data | Comments |
---|---|---|---|---|---|---|---|
848 BATC k1063 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 848 BATC k1063 ** | 848 BATC k1063 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
823 823_v1 k1027 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 823 823_v1 k1027 | ||||
390 BATC k1052 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 390 BATC k1052 ** | 390 BATC k1052 ** | |||
VR Bernstein k1040 *** Retired! | Nicholas U. Mayall 4-meter Telescope | Mosaic | VR Bernstein k1040 *** Retired! | VR Bernstein k1040 *** Retired! | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=5934A, FWHM=2079A, PEAK TRANSMISSION=95.3%. | ||
607 BATC k1058 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 607 BATC k1058 ** | 607 BATC k1058 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
Bw NDWFS k1025 | Nicholas U. Mayall 4-meter Telescope | Mosaic | Bw NDWFS k1025 | Bw NDWFS k1025 | |||
815 815_v2 k1046 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v2 k1046 | 815 815_v2 k1046 | |||
848 BATC k1063 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 848 BATC k1063 ** | 848 BATC k1063 ** | |||
ha12 H-alpha+12nm k1012 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha12 H-alpha+12nm k1012 | ha12 H-alpha+12nm k1012 | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=6672A, FWHM=83A, PEAK TRANSMISSION=87.3%. | ||
823 823_v1 k1027 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 823 823_v1 k1027 | 823 823_v1 k1027 | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1) and the CTIO 4m (f/2.9). At the KPNO 4m the properties of this filter are: CWL=8170A, FWHM=71A, PEAK TRANSMISSION=91.5%. | ||
420 BATC k1053 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 420 BATC k1053 ** | 420 BATC k1053 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
V Harris k1003 | Nicholas U. Mayall 4-meter Telescope | Mosaic | V Harris k1003 | V Harris k1003 | |||
607 BATC k1058 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 607 BATC k1058 ** | 607 BATC k1058 ** | |||
M Washington k1007 | Nicholas U. Mayall 4-meter Telescope | Mosaic | M Washington k1007 | M Washington k1007 | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=5168A, FWHM=1126A, PEAK TRANSMISSION=86.5%. | ||
Bw NDWFS k1025 | Nicholas U. Mayall 4-meter Telescope | Mosaic | Bw NDWFS k1025 | Bw NDWFS k1025 | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1) and the CTIO 4m (f/2.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=4091A, FWHM=1250A, PEAK TRANSMISSION=91.7%. | ||
815 815_v2 k1046 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v2 k1046 | A comparison of this filter with the older version of this filter (k1026): | |||
918 BATC k1064 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 918 BATC k1064 ** | 918 BATC k1064 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
420 BATC k1053 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 420 BATC k1053 ** | 420 BATC k1053 ** | |||
V Harris k1003 | Nicholas U. Mayall 4-meter Telescope | Mosaic | V Harris k1003 | ||||
Un Steidel k1041 | Nicholas U. Mayall 4-meter Telescope | Mosaic | Un Steidel k1041 | Un Steidel k1041 | |||
666 BATC k1059 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 666 BATC k1059 ** | 666 BATC k1059 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
815 815_v2 k1046 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v2 k1046 | 815 815_v2 k1046 | Below is a plot of this filter as simulated in different f/ratio beams. At the KPNO 4m f/3.1 the properties of this filter are: CWL= 8109.85A FWHM= 68.62A PEAK TRANSMISSION= 81.42% at 8122A | ||
918 BATC k1064 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 918 BATC k1064 ** | 918 BATC k1064 ** | |||
ha16 H-alpha+16nm k1013 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha16 H-alpha+16nm k1013 | ha16 H-alpha+16nm k1013 | Below is a plot of the transmission of this filter when used at telescopes with differing focal ratios and central obscurations; the KPNO 4m (f/3.1), the CTIO 4m (f/2.9), and the WIYN 0.9m (f/7.9). At the KPNO 4m f/3.1 the properties of this filter are: CWL=6705A, FWHM=81A, PEAK TRANSMISSION=91.7%. | ||
918R 918R_v1 k1028 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 918R 918R_v1 k1028 | 918R 918R_v1 k1028 | |||
454 BATC k1054 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 454 BATC k1054 ** | 454 BATC k1054 ** | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. | ||
wrc3 WR CIII k1021 | Nicholas U. Mayall 4-meter Telescope | Mosaic | wrc3 WR CIII k1021 | wrc3 WR CIII k1021 | Below is a plot of this filter as simulated in different f/ratio beams. At the KPNO 4m f/3.1 the properties of this filter are: CWL=4657A FWHM=52.6A PEAK TRANSMISSION=68.23% | ||
666 BATC k1059 ** | Nicholas U. Mayall 4-meter Telescope | Mosaic | 666 BATC k1059 ** | 666 BATC k1059 ** | |||
wrc4 WR CIV k1024 | 41.79 | 5828.71 | Nicholas U. Mayall 4-meter Telescope | Mosaic | wrc4 WR CIV k1024 | wrc4 WR CIV k1024 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
o2 OII c6012 | 50.00 | 3727.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | o2 OII c6012 | o2 OII c6012 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
o3 OIII c6014 | 50.00 | 4990.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | o3 OIII c6014 | o3 OIII c6014 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
wrhe2 WR HeII k1023 | 50.31 | 4702.60 | Nicholas U. Mayall 4-meter Telescope | Mosaic | wrhe2 WR HeII k1023 | wrhe2 WR HeII k1023 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
wr475 WR 475 k1022 | 51.27 | 4764.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | wr475 WR 475 k1022 | wr475 WR 475 k1022 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
wrc3 WR CIII k1021 | 51.71 | 4666.15 | Nicholas U. Mayall 4-meter Telescope | Mosaic | wrc3 WR CIII k1021 | wrc3 WR CIII k1021 | Note that there is a shift in central wavelength when placed in different f/ratio beams.At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
O3 OIII N2 k1014 * | 55.55 | 5024.90 | Nicholas U. Mayall 4-meter Telescope | Mosaic | O3 OIII N2 k1014 * | O3 OIII N2 k1014 * | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
823 823_v2 k1047 | 68.02 | 8238.79 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 823 823_v2 k1047 | 823 823_v2 k1047 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: This is a replacement of the old Rhoads 823 filter (k1027) was purchased. See below for a comparison of the two filters. |
815 815_v2 k1046 | 68.53 | 8152.64 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v2 k1046 | 815 815_v2 k1046 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: This is a replacement for the old Rhoads 815 filter (k1026) |
815 815_v1 k1026 | 70.36 | 8152.10 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 815 815_v1 k1026 | 815 815_v1 k1026 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note:In December 2003 a replacement for this filter (k1046) was purchased. See below for a comparison between the two filters. |
823 823_v1 k1027 | 70.61 | 8232.04 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 823 823_v1 k1027 | 823 823_v1 k1027 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. Note: In December 2003 a replacement for this filter (k1047) was purchased. See below for a comparison of the two filters. |
ha8 H-alpha+8nm c6011 | 80.00 | 6650.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha8 H-alpha+8nm c6011 | ha8 H-alpha+8nm c6011 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
s2 SII c6013 | 80.00 | 6725.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | s2 SII c6013 | s2 SII c6013 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
ha H-alpha c6009 | 80.00 | 6563.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha H-alpha c6009 | ha H-alpha c6009 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
ha4 H-alpha+4nm k1010 | 80.48 | 6620.52 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha4 H-alpha+4nm k1010 | ha4 H-alpha+4nm k1010 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
ha H-alpha k1009 | 80.62 | 6574.74 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha H-alpha k1009 | ha H-alpha k1009 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
ha16 H-alpha+16nm k1013 | 81.10 | 6730.72 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha16 H-alpha+16nm k1013 | ha16 H-alpha+16nm k1013 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
918R 918R_v1 k1028 | 81.22 | 9210.96 | Nicholas U. Mayall 4-meter Telescope | Mosaic | 918R 918R_v1 k1028 | 918R 918R_v1 k1028 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
ha8 H-alpha+8nm k1011 | 81.33 | 6654.19 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha8 H-alpha+8nm k1011 | ha8 H-alpha+8nm k1011 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer See the plot at the bottom of the page. |
ha12 H-alpha+12nm k1012 | 82.95 | 6698.53 | Nicholas U. Mayall 4-meter Telescope | Mosaic | ha12 H-alpha+12nm k1012 | ha12 H-alpha+12nm k1012 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
D51 DDO 51 c6008 | 154.00 | 5130.00 | Nicholas U. Mayall 4-meter Telescope | Mosaic | D51 DDO 51 c6008 | D51 DDO 51 c6008 | Note: The central wavelength of CTIO Mosaic narrow band filters (actually all filters, but is very significant for narrow band filters) is shifted ~15A to the BLUE in the f/2.87 beam of the Blanco 4m + PFADC corrector as compared to the transmission measured in parallel light. The central wavelength quoted below is nominally for when the filter is used at PF, with the ~15A shift included. Furthermore, the filter transmission curve presented below shows the simulated filter transmission curve for the Blanco 4m + PFADC f/2.87 beam. |
D51 DDO 51 k1008 | 162.90 | 5145.20 | Nicholas U. Mayall 4-meter Telescope | Mosaic | D51 DDO 51 k1008 | D51 DDO 51 k1008 | Note that there is a shift in central wavelength when placed in different f/ratio beams. At the KPNO 4meter f/3.1 beam this corresponds to a shift of approximately 12 Angstroms bluer; at the CTIO 4meter f/2.9 this corresponds to a shift of approximately 15 Angstroms bluer; at the WIYN 0.9m f/7.9 this corresponds to a shift of approximately 5 Angstroms bluer. See the plot at the bottom of the page. |
Pagination
Last updated: 2009 Dec 9, ARW
Staff Contacts:
Sean Points: spointsATctio.noao.edu
Alistair Walker: awalkerATctio.noao.edu
Updated on June 5, 2021, 8:00 pm